From ambrose@fnal.gov Thu Nov 8 09:12:41 2001 Date: Thu, 08 Nov 2001 09:11:49 -0600 From: David Ambrose To: COT Group -- Adam , Alec , Aseet , Ashutosh Kotwal , Ayana , Bill Orejudos , Bill Robertson , Bob Wagner , Dave Ambrose , Eiko , Eric James , Evelyn , Greg Veramendi , Jay , JC Yun , Ken Schultz , Kevin Burkett , Kevin Pitts , Kirby , Marina Brozovic , Michael Lindgren , Morris , Nigel Lockyer , Paris , Peter Tamburello , Peter Wittich , pjw , Reinhard Eckmann , Rob Snihur , Robyn Madrak , Ron Moore , Ting , Tom Phillips , Young-Kee Subject: owl report Starting to button up detector from October shutdown. Peter and I looked at the following... Crate 4 is having problems activating in run control, so is left out (will try a new TRACER): --> Swapped TRACER #103 from cleanroom with crate #4 TRACER #152, but still doesn't get DONE LED to come on. --> I talked with Fred about this and he will take a look. Mainly have some plug in problems here: SL4-226 (D,579,18-17-3): 12 dead, 00 hot!, 00 warm, 00 null SL4-227 (D,579,18-17-3): 09 dead, 03 hot!, 00 warm, 00 null --> 2 HVD 1 TRK --> Needs a CV jumper to ASDQ. SL5-004 (A,018,10-12-2): 00 dead, 12 hot!, 00 warm, 00 null SL5-005 (A,018,10-12-2): 00 dead, 11 hot!, 01 warm, 00 null --> Has developed noise during shutdown. Haven't looked yet. SL7-056 (A,092,01-02-0): 03 dead, 09 hot!, 00 warm, 00 null SL7-057 (A,092,01-02-0): 03 dead, 09 hot!, 00 warm, 00 null --> Fixed bad u-socket plug-in. SL8-235 (B,367,15-14-3): 12 dead, 00 hot!, 00 warm, 00 null --> Fixed bad TDC plug-in. Still to do from last night: SL5-220 (C,518,17-13-2): 00 dead, 02 hot!, 09 warm, 00 null SL5-221 (C,518,17-13-2): 00 dead, 00 hot!, 03 warm, 07 null SL5-223 (C,519,17-13-3): 00 dead, 02 hot!, 03 warm, 00 null --> Thought this was double-calib, but just has smaller pos calib. Swapped 5-220 with 5-222, but still have NULL noise and higher DTH with 5-220, so HAS BEEN SWAPPED BACK. SL8-232 (B,366,15-14-2): Q = 32.6 (23.9+/-2.1) +8.7 SL8-233 (B,366,15-14-2): Q = 31.5 (23.9+/-2.1) +7.6 --> Got new ribbon, so is probably CV socket. Try to wiggle back connection to QEN (is presently floating). --> Wiggled until QEN came back, but not likely to hold. Analog monitor work (from Ayana): --> Plugged in/repaired connections for 7 channels on the West, and 3 on East (out of 96 on East + West). --> Only 4 known bad channels on East, no bad channels on West.